Selecting a diagram

Installing an HCP RAIN System - Final On-Site Setup

Version
9.7.x
File Size
35463 KB
Audience
anonymous
Part Number
MK-98ARC016-35

To determine which racking and connection diagram to use, you need the HCP system packing list. If the packing list includes more than one HCP G11 Node system, select the diagram for each system individually.

To select a diagram for an HCP system:

  1. In the packing list, see the "Configuration Parameters" section for the HCP system configuration.
    • If the system configuration is "HCP G11 Node rack: Non-appliance configuration," see HCP G11 Node base and expansion diagrams
    • If the system configuration is "HCP G11 Node rack: appliance configuration (combine HCP G11 Node and S11/VSP)" and the system does not include any HCP G11 Nodes, see HCP G11 Node appliance with VSP Gx00 models
    • If the system configuration is "HCP G11 Node rack: appliance configuration (combine HCP G11 Node and S11/VSP)" and system includes one, two, or three HCP G11 Nodes, see HCP G11 Node appliance with S11 and Optional VSP Gx00 models
  2. From the diagrams in the applicable section, select the diagram that includes the PDU part number listed for the applicable system configuration in the packing list.
  3. If the system configuration is "G11 rack: Non-appliance configuration," the PDU part number is 3P30A-24C13-6C19UL.P or 3P32A-24C13-6C19CE.P, and the system configuration description in the packing list is:
    • "G11 rack: Install PDU with cables orientated towards ceiling," use HCP G11 base and expansion with Three-phase Americas (3P30A-24C13-6C19UL) – Top power
    • "G11 rack: Install PDU with cables orientated towards floor," use Three-phase Americas (3P30A-24C13-6C19UL) – Bottom power
    For example, use HCP G11 base and expansion with Three-phase Americas (3P30A-24C13-6C19UL) – Top power if in the packing list:
    • The HCP system is "G11 rack: Non-appliance configuration"
    • The PDU model number is 3P30A-24C13-6C19UL.P
    • The description is "G11 rack: Install PDU with cables orientated towards ceiling"
    Each diagram shows the hardware configuration for a single rack. If the HCP system includes additional components that don't fit in the rack, ensure that you have additional racks, as needed.