HCP with internal storage system hardware

Installing an HCP RAIN System - Final On-Site Setup

Version
9.7.x
File Size
35463 KB
Audience
anonymous
Part Number
MK-98ARC016-35

HCP with internal storage system hardware consists of:

  • Nodes with internal storage (a typical starter system has four nodes). The nodes are numbered from 101 through 104 for a four-node system. The node numbers increase by one for each additional node.

    The nodes in an HCP with internal storage system are HCP G11 servers.

  • HCP S Series Nodes. The possible node models are:
    • S11
    • S31
  • Ethernet switches and cables for networking. The switches in an HCP with internal storage can be for one or ten gigabyte back-end network configurations. The possible switch models are:
    • Supported one gigabyte switch:
      • Brocade ICX 6430
    • Supported ten gigabyte switches:
      • Arista 7020
      • Brocade VDX 6740
      • Cisco Nexus 5548UP
      • Cisco Nexus 5596UP
    • Supported 25 gigabyte switch:
      • 93180YC-FX3 NX-OS
    • Additional infrastructure items such as a rack and Power Distribution Units (PDUs).

An HCP system uses a back-end network, front-end network, and, in certain configurations, a management network. The isolated back-end network connects the HCP nodes to each other through one or two Ethernet switches, depending on your network configuration and switch model. Each node has a pair of bonded Ethernet ports for connecting to these switches. Node port locations vary, depending on the network configuration the node was constructed for.

Each node is configured with an additional pair of bonded Ethernet ports that allows external applications to access the system. The recommended setup includes either two independent Ethernet switches that connect these ports to the front-end network (that is, your corporate network) or one Ethernet switch with both HCP and the switch configured for active-active bonding.

The front-end network switches and the cables for connecting them to the HCP nodes are not included with the delivered HCP with internal storage system. The cables are customer supplied. You can use any reasonable Ethernet switch model for the front-end network, but you cannot use the back-end switches for the front-end network.

Each node also has an additional management network Ethernet port that allows for the creation of the management network. The management network segregates system and tenant administration, management API, SNMP, syslog, outgoing SMTP, and SSH traffic from the [hcp_system] network.

The following figure shows the standard architecture of an HCP with internal storage system. This system has four nodes, two back-end switches (on the left), and two front-end switches (on the right).



The following table describes the cables in this figure.

Cable Connects from Connects to
Red and blue Ethernet Back-end network interface cards (NICs) in each node Back-end switches
Green and yellow Ethernet Front-end NICs in each node Front-end switches
Purple Ethernet Back-end switches Each other
Black power Each node Two PDUs
Each Back-end switch One PDU