1 |
POST code |
Green |
Solid |
POST is in progress. |
2 |
Server module status |
Green |
Solid |
The server module is functioning properly. |
Blinking |
- Flashing 2 times per second: Baseboard management controller is coming online.
- Flashing 4 times per second: Baseboard management controller is functioning properly.
|
3 |
Server module fault |
Amber |
Solid |
A server module component has a fault condition. |
Blinking |
The server module is powering on. |
4 |
Server module identify |
Blue |
Solid |
During normal operation, beaconing is on. |
Blinking |
During initial power on, a power and cooling module has a fault condition. |
5 |
SAS ports on optional SAS PCIe card |
Green |
Solid |
The port has a link, and activity is occurring on the link. |
Amber |
Blinking |
- Flashing 1 time per second: SAS port or cable has a noncritical fault condition.
- Flashing 3 times per second: SAS port beaconing is on.
|
6 |
Onboard SAS ports |
Green |
Solid |
The port has a link, and activity is occurring on the link. |
Amber |
Blinking |
- Flashing 1 time per second: SAS port or cable has a noncritical fault condition.
- Flashing 3 times per second: SAS port beaconing is on.
|
7 |
1Gb Ethernet link activity/network speed |
Left |
Solid green |
The port has a link. |
Blinking green |
Port activity is occurring on the link.. |
Right |
Solid green |
Link speed is 1Gbps. |
Blinking green |
Link speed is 100Mbps or 10Mbps. |
8 |
SFP28 25/10Gb Ethernet link activity/network speed |
Left |
Solid green |
The port has a link. |
Blinking green |
Port activity is occurring on the link.. |
Right |
Solid green |
Link speed is 25 Gbps. |
Solid amber |
Link speed is 10 Gbps. |