The HCP S Series Node uses alerts to communicate current conditions. Each alert has a triggering event that is recorded in the S Series Node event log. Not all events trigger alerts, but for those that do, the alert text is the same as the detailed message text for the triggering event.
The table below lists the messages that the S Series Node can write to the event log. For each message, the table shows:
- The message ID
- The detailed message text
- An explanation of the event that caused the message to be logged
- The action, if any, you should take in response to the event
- The severity of the event:
- N = Notice
- W = Warning
- E = Error
- An indication of whether the event triggers an alert
The messages are listed in order by message ID.
ID | Message | Explanation | Action | Sev. | Alert |
---|---|---|---|---|---|
1002 | A test message has been sent to the syslog servers at the following IP addresses: ip-address-list | A user sent a test message to the syslog servers. | No action is required. | N | No |
2619 | An attempt to restart or shut down a server module failed (originating IP ip-address). | An attempt to restart or shut down a server module failed. The server module may already be down. | No action is required. | N | No |
2621 | Server module server-module-number failed to apply configuration changes. | An attempt to update the configuration of a server module failed. The internal configuration does not match the reported configuration. | Contact your authorized service provider. | E | No |
2622 | Server module server-module-number failed to apply access configuration changes. | An attempt to update a configuration setting for external access to a server module failed. The internal configuration does not match the reported configuration. | Contact your authorized service provider. | E | No |
2625 | Server module server-module-number is now synchronized with time server time-server-ip-address. | A server module has been synchronized with an external time server. | No action is required. | N | No |
2626 | Server module server-module-number lost synchronization with time server time-server-ip-address. | An error occurred in synchronizing the time on a server module with the time on an external time server. | Check network connectivity and that network and time server settings are correct. | E | Yes |
2627 | Server module server-module-number is not synchronized with a time server. | An error occurred in synchronizing the time on a server module with the time on an external time server. | Check network connectivity and that network and time server settings are correct. | E | Yes |
2629 | File system file-system-name is percent-full% full on server module server-module-number. | A file system on a server module is reaching capacity. | Contact your authorized service provider. | W | Yes |
2630 | File system file-system-name is percent-full% full on server module server-module-number. Data access will be disabled if the file system usage reaches capacity. | A file system on a server module is nearly full. Data access will be disabled if the file system usage reaches capacity. | Contact your authorized service provider. | E | Yes |
2631 | Network interface network-device on server module server-module-number is down. | A network interface went down. | Check network connectivity. If a problem exists, contact your authorized service provider. | E | Yes |
2632 | Server module server-module-number is unavailable. | A server module is unavailable. | If this event is unexpected and the server module does not restart automatically, contact your authorized service provider. Do not try to restart the server module manually, as that may cause the loss of information needed to diagnose the problem. | E | Yes |
2634 | Communication from server module server-module-number to DNS servers dns-server-ip-address-list failed. | The HCP S Series Node was unable to establish connectivity to the DNS servers. | Check DNS settings. | E | Yes |
2635 | Server module server-module-number is available. | The HCP S Series software started on a server module. | No action is required | N | No |
2636 | Server module server-module-number is unavailable. | A server module is unavailable due to an in-progress upgrade. | If the server module does not restart automatically after the upgrade is complete, contact your authorized service provider. | N | Yes |
2637 | Server module server-module-number temperature sensor sensor-name has detected a temperature error condition; status: temperature-status. | A server-module temperature sensor is reporting a temperature that is out of the recommended range. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2638 | Server module server-module-number temperature sensor sensor-name has detected a temperature warning condition; status: temperature-status. | A server-module temperature sensor is reporting a temperature that is out of the recommended range. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | W | Yes |
2639 | Server module server-module-number temperature sensor sensor-name is no longer reporting an abnormal temperature condition. | A server-module temperature sensor is no longer reporting an abnormal temperature condition. | No action is required. | N | No |
2640 | Fan sensor sensor-name has triggered an alarm on server module server-module-number; status: fan-status. | A fan sensor is reporting a fan speed that is out of the recommended range. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2641 | Fan sensor sensor-name has triggered a warning on server module server-module-number; status: fan-status. | A fan sensor is reporting a fan speed that is out of the recommended range. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | W | Yes |
2642 | Fan sensor sensor-name has removed the alarm on server module server-module-number. | A fan sensor is reporting a return to an acceptable fan speed. | No action is required. | N | No |
2643 | Server module server-module-number voltage sensor sensor-name has detected a voltage error condition; status: voltage-status. | A server-module voltage sensor is reporting a voltage that is out of the recommended range. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2644 | Server module server-module-number voltage sensor sensor-name has detected a voltage warning condition; status: voltage-status. | A server-module voltage sensor is reporting a voltage that is out of the recommended range. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | W | Yes |
2645 | Server module server-module-number voltage sensor sensor-name is no longer reporting an abnormal voltage condition. | A server-module voltage sensor is no longer reporting an abnormal voltage condition. | No action is required. | N | No |
2646 | Power supply power-supply-name has triggered an alarm on server module server-module-number; status: power-supply-status. | A power supply is reporting a problem. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2647 | Power supply power-supply-name has triggered a warning on server module server-module-number; status: power-supply-status. | A power supply is reporting a problem. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | W | Yes |
2648 | Power supply power-supply-name has removed an alarm on server module server-module-number. | A power supply is reporting that it has returned to a fully functional state. | No action is required. | N | No |
2649 | Server module server-module-number processor processor-name has an error condition; status: processor-status. | A server-module processor has an error condition. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2650 | Server module server-module-number processor processor-name has a warning condition; status: processor-status. | A server-module processor has a warning condition. | Check that the server module is functioning properly. If a problem exists, contact your authorized service provider. | W | Yes |
2651 | Server module server-module-number processor processor-name is no longer in an abnormal condition. | A server-module processor is now functioning properly. | No action is required. | N | No |
2652 | File system file-system-name is percent-full% full on server module server-module-number. Data access has been disabled. | A file system on a server module is full. Data access has been disabled. | Contact your authorized service provider. | E | Yes |
2653 | Server module server-module-number swap utilization is too high. | Swap utilization on a server module is too high. | Contact your authorized service provider. | N | No |
2654 | Server module server-module-number CPU load average is too high. | The CPU load average on a server module is too high. | Contact your authorized service provider. | N | No |
2655 | Server module server-module-number BMC is no longer accessible. | The baseboard management controller (BMC) in a server module is inaccessible. | Check that the server module is powered on and that the server interconnect network is healthy. | E | Yes |
2656 | Server module server-module-number BMC is now accessible. | The baseboard management controller (BMC) in a server module is accessible. | No action is required. | N | No |
2657 | Server module server-module-number is powered off. | A server module is powered off. | Check the server module power and network connectivity. | E | Yes |
2658 | Server module server-module-number was powered on. | A server module was powered on. | No action is required. | N | No |
2659 | Network interface network-device is not operating at the correct speed on server module server-module-number. | Either the network interfaces in a bonded network interface are not operating at the same speed, or they are not operating at the requested speed. | Check that the server module is functioning properly and that the network infrastructure is configured correctly. If the problem persists, contact your authorized service provider. | W | Yes |
2660 | Network interface network-device is now operating at the correct speed on server module server-module-number. | A network interface is now operating at the correct speed. | No action is required. | N | No |
2661 | Network interface network-device is not operating at the correct MTU on server module server-module-number. | A network interface is not operating at the requested MTU. | Check that the server module is functioning properly and that the network infrastructure is configured correctly. If the problem persists, contact your authorized service provider. | W | Yes |
2662 | Network interface network-device is now operating at the correct MTU on server module server-module-number. | A network interface is now operating at the correct MTU. | No action is required. | N | No |
2665 | Network interface network-device is not operating in the correct bonding mode on server module server-module-number. | A network interface is not operating in the correct bonding mode. | Check that the server module is functioning properly and that the network infrastructure is configured correctly. If the problem persists, contact your authorized service provider. | W | Yes |
2666 | Network interface network-device is now operating in the correct bonding mode on server module server-module-number. | A network interface is now operating in the correct bonding mode. | No action is required. | N | No |
2667 | Server module server-module-number swap utilization is below the error threshold. | Swap utilization on a server module is no longer too high. | No action required. | N | No |
2668 | Server module server-module-number CPU load average is below the error threshold. | The CPU load average on a server module is no longer too high. | No action required. | N | No |
2669 | All DNS servers are accepting communications. | The HCP S Series Node can communicate with all the DNS servers. | No action required. | N | No |
2670 | Network interface network-device on server module server-module-number is up. | A network interface that was down is now up. | No action is required. | N | No |
2671 | Network interface network-device on server module server-module-number is connected to an active network but should not be. | An access network port that is set to OFF is connected to an active network. | Check that the access network port connections match the port settings for the S Series Node. | E | Yes |
2672 | The connection expectation for network interface network-device on server module server-module-number is now satisfied. | A port connection expectation is now satisfied. | No action is required. | N | No |
2673 | File system file-system-name is percent-full% full on server module server-module-number. | A file system that was reaching capacity is no longer reaching capacity. | No action is required. | N | No |
2674 | maintenance-procedure-type maintenance procedure was started. | A maintenance procedure was started. | No action is required. | N | No |
2675 | maintenance-procedure-type maintenance procedure was completed. | A maintenance procedure was completed. | No action is required. | N | No |
2676 | maintenance-procedure-type maintenance procedure was canceled. | A maintenance procedure was canceled. | No action is required. | W | No |
2678 | maintenance-procedure-type maintenance procedure timed out. | A maintenance procedure timed out. | No action is required. | W | No |
2679 | maintenance-procedure-type maintenance procedure finished with errors. | A maintenance procedure finished with errors. | Use a new maintenance procedure to correct the errors. | E | No |
2680 | Server module server-module-number hardware is unsupported (vendor: server-module-vendor, product: server-module-model, rev: server-module-firmware-revision). | Server module hardware is unsupported. | Contact your authorized service provider. | E | Yes |
2681 | Sever module server-module-number hardware is now supported (vendor: server-module-vendor, product: server-module-model, rev: server-module-firmware-revision). | Server module hardware is now supported. | No action is required. | N | No |
2682 | An OS SSD in server module server-module-number is unsupported (vendor: ssd-vendor, product: ssd-model, rev: ssd-firmware-revision, wwid: ssd-wwid). | An OS SSD is unsupported. | Contact your authorized service provider. | E | Yes |
2683 | An OS SSD in server module server-module-number is now supported (vendor: ssd-vendor, product: ssd-model, rev: ssd-firmware-revision, wwid: ssd-wwid). | An OS SSD is now supported. | No action is required. | N | No |
2684 | A drive error was detected (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive error was detected. | After data has been migrated off of the drive, replace the drive. Data is guaranteed to have been migrated off the drive when the count of bytes under repair shown is zero. | E | Yes |
2685 | A drive error has been cleared (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, drive-wwid: wwid). | A data drive error was cleared. | No action is required. | N | No |
2686 | An OS SSD error was detected in server module server-module-number (serial number: ssd-serial-number, wwid: ssd-wwid). | An OS SSD error was detected. | Replace the SSD. | E | Yes |
2687 | An OS SSD error in server module server-module-number has been cleared (serial number: ssd-serial-number, wwid: ssd-wwid). | An OS SSD error was cleared. | No action is required. | N | No |
2688 | A drive is not properly configured for internal monitoring (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive is not properly configured for internal monitoring. | Contact your authorized service provider. | W | Yes |
2689 | A drive is now properly configured for internal monitoring (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive is now properly configured for internal monitoring. | No action is required. | N | No |
2690 | An OS SSD in server module server-module-number is not properly configured for internal monitoring (serial number: ssd-serial-number, wwid: ssd-wwid). | An OS SSD is not properly configured for internal monitoring. | Contact your authorized service provider. | W | Yes |
2691 | An OS SSD in server module server-module-number is now properly configured for internal monitoring (serial number: ssd-serial-number, wwid: ssd-wwid). | An OS SSD is now properly configured for internal monitoring. | No action is required. | N | No |
2692 | The HCP S Series Node license expired on license-expiration-date. | The HCP S Series Node license is expired. | Contact your authorized service provider. | E | Yes |
2693 | The HCP S Series Node license is no longer expired (expiration: license-expiration-date). | The HCP S Series Node license is no longer expired. | No action is required. | N | No |
2694 | The licensed capacity for the HCP S Series Node is exceeded (capacity: actual-total-capacity, licensed: licensed-capacity). | The physical capacity of the HCP S Series Node exceeds the licensed capacity. | Contact your authorized service provider. | E | Yes |
2695 | The licensed capacity for the HCP S Series Node is no longer exceeded (capacity: actual-total-capacity, licensed: licensed-capacity). | The physical capacity of the HCP S Series Node no longer exceeds the licensed capacity. | No action is required. | N | No |
2696 | The HCP S Series Node is not licensed. | The HCP S Series Node is not licensed. | Contact your authorized service provider. | E | Yes |
2697 | The HCP S Series Node is now licensed (serial number: s-series-node-serial-number, quote number: quote-number, capacity: licensed-capacity, expiration: license-expiration-date). | The HCP S Series Node is now licensed. | No action is required. | N | No |
2698 | A drive error was detected (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data drive error was detected. | After data has been migrated off of the drive, replace the drive. Data is guaranteed to have been migrated off the drive when the count of bytes under repair is zero. | N | Yes |
2699 | Server module server-module-number beaconing is on. | Beaconing is on for a server module. | No action is required. | N | Yes |
2700 | Server module server-module-number beaconing is now off. | Beaconing is now off for a server module. | No action is required. | N | No |
2701 | A database drive is percent-worn% worn (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A database drive is close to the end of its expected life span. | Replace the drive. | W | Yes |
2702 | Network interface network-device on server module server-module-number is down. | A network interface went down. | Check network connectivity. If a problem exists, contact your authorized service provider. | N | No |
2703 | The password for the user account with username username was updated. | A user updated a user account password. | No action is required. | N | No |
2704 | A user with username username successfully logged in to the HCP S Series Management Console from ip-address:port-number. | A user login to the HCP S Series Management Console was successful. | No action is required. | N | No |
2705 | A user with username username failed to log in to the HCP S Series Management Console from ip-address:port-number. | A user attempt to log in to the HCP S Series Management Console failed. | No action is required. | W | No |
2706 | An attempt was made to access the HCP S Series Node with the unknown username username from ip-address:port-number. | A user tried to access the HCP S Series Management Console or management API with an unknown username. | Have the user try again with a valid username and password. | W | No |
2707 | An attempt to access the HCP S Series Node with username username from ip-address:port-number failed because the password is invalid. | A user tried to access the HCP S Series Management Console or management API with an invalid password. | Have the user try again with a valid username and password. | W | No |
2708 | The user account with ID user-account-id and username username has been automatically disabled because it had failed-attempt-threshold or more failed attempts to access the HCP S Series Node. | A user account was automatically disabled due to too many failed attempts to access the HCP S Series Management Console or management API. | Reenable the user account. Then have the user try again with a valid username and password. | W | No |
2709 | An attempt to access the HCP S Series Node with user account ID user-account-id and username username failed because the account is disabled. | A user tried to access the HCP S Series Management Console or management API with a disabled user account. | Reenable the user account to allow the user to access the applicable interface. | W | No |
2710 | The user account with ID user-account-id and username username has been automatically disabled because it has been inactive for number-of-days or more consecutive days. | A user account was automatically disabled because it was inactive for too many days. | If the account owner should have access to the HCP S Series Node, re-enable the user account. | W | No |
2711 | An attempt to log in to the HCP S Series Management Console with user account ID user-account-id and username username failed because the account is disabled. | A user tried to log in to the HCP S Series Management Console with a disabled user account. | Reenable the user account to allow the user to log in. | W | No |
2712 | An attempt was made to log in to the HCP S Series Management Console with the unknown username username from ip-address:port-number. | A user tried to log in to the HCP S Series Management Console with an unknown username. | Have the user try again with a valid username and password. | W | No |
2713 | A user with user account ID user-account-id from ip-address:port-number failed to access a requested page in the HCP S Series Management Console. | The user account password or roles may have been modified since the last request to access a page in the HCP S Series Management Console. | Have the user log in to the Console again with a valid username and password. | W | No |
2714 | The user account with ID user-account-id and username username has been automatically re-enabled after being disabled for number-of-minutes minutes. | A disabled user account was automatically re-enabled. | No action is required. | N | No |
2715 | Network interface network-device on server module server-module-number is not connected to an active network but should be. | An access network port that is set to ON is not connected to an active network. | Check that the access network port connections match the port settings for the S Series Node. | E | Yes |
2716 | Beaconing has been requested for a component. | A user requested beaconing for a component. | No action is required. | N | No |
2720 | A database backup finished successfully. | The HCP S Series Node database was successfully backed up. | No action is required. | N | No |
2721 | A database backup failed. | An attempt to back up the HCP S Series Node database failed. | Contact your authorized service provider. | E | No |
2750 | Server module server-module-number operating system partition partition-name is being synchronized (percent-complete). | Operating system partition synchronization is in progress. | No action is required. | N | Yes |
2751 | Server module server-module-number operating system partition partition-name synchronization is complete. | Operating system partition synchronization is complete. | No action is required. | N | No |
2752 | Server module server-module-number database partition is being synchronized (percent-complete). | Database partition synchronization is in progress. | No action is required. | N | Yes |
2753 | Server module server-module-number database partition synchronization is complete. | Database partition is synchronization is complete. | No action is required. | N | No |
2754 | Server module server-module-number operating system partition partition-name is being recovered (percent-complete). | Operating system partition recovery is in progress. | No action is required. | W | Yes |
2755 | Server module server-module-number operating system partition partition-name recovery is complete. | Operating system partition recovery is complete. | No action is required. | N | No |
2756 | Server module server-module-number database partition is being recovered (percent-complete). | Database partition recovery is in progress. | No action is required. | W | Yes |
2757 | Server module server-module-number database partition recovery is complete. | Database partition recovery is complete. | No action is required. | N | No |
2758 | Server module server-module-number operating system partition partition-name is degraded. | An operating system partition is degraded. | Replace the applicable SSD. | E | Yes |
2759 | Server module server-module-number operating system partition partition-name is no longer degraded. | An operating system partition is no longer degraded. | No action is required. | N | No |
2760 | A server module server-module-number database partition is degraded. | A database partition is degraded. | No action is required. | E | Yes |
2761 | A server module server-module-number database partition is no longer degraded. | A database partition is no longer degraded. | No action is required. | N | No |
2762 | Drive failed (enclosure: enclosure-number, slot: slot-number, FRU part number: part-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive failed. | Remove or replace the drive. | E | Yes |
2763 | Drive failed (enclosure: enclosure-number, slot: slot-number, FRU part number: part-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive failed. | A data or database drive has failed but does not yet require replacement. Replace the drive when the HCP S Series Node reports that the threshold for drive replacement has been reached. | N | Yes |
2764 | An OS SSD error was detected in server module server-module-number (FRU part number: part-number, serial number: ssd-serial-number, wwid: ssd-wwid). | An OS SSD error was detected. | Replace the SSD. | E | Yes |
2765 | Server module server-module-number operating system partition partition-name is degraded (FRU part number: part-number). | An operating system partition is degraded. | Replace the applicable SSD. | E | Yes |
2800 | The cover for enclosure enclosure-number has been opened outside of a maintenance procedure. | An enclosure cover is open outside of a maintenance procedure. | Close the enclosure cover. | E | Yes |
2801 | The cover for enclosure enclosure-number has been opened during a maintenance procedure. | An enclosure cover is open during a maintenance procedure. | No action is required. | N | Yes |
2802 | The cover for enclosure enclosure-number has been closed. | An enclosure cover was closed. | No action is required. | N | No |
2821 | Enclosure enclosure-number temperature sensor sensor-name has detected an over-temperature error condition. | An enclosure temperature sensor is reporting an over-temperature error condition. | Check that the enclosure power supplies are functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2822 | Enclosure enclosure-number temperature sensor sensor-name is no longer reporting an over-temperature error condition. | An enclosure temperature sensor is no longer reporting an over-temperature error condition. | No action is required. | N | No |
2823 | Enclosure enclosure-number temperature sensor sensor-name has detected an over-temperature warning condition. | An enclosure temperature sensor is reporting an over-temperature warning condition. | Check that the enclosure power supplies are functioning properly. If a problem exists, contact your authorized service provider | W | Yes |
2824 | Enclosure enclosure-number temperature sensor sensor-name is no longer reporting an over-temperature warning condition. | An enclosure temperature sensor is no longer reporting an over-temperature warning condition. | No action is required. | N | No |
2825 | Enclosure enclosure-number temperature sensor sensor-name has detected an under-temperature error condition. | An enclosure temperature sensor is reporting an under-temperature error condition. | Check that the enclosure power supplies are functioning properly. If a problem exists, contact your authorized service provider. | E | Yes |
2826 | Enclosure enclosure-number temperature sensor sensor-name is no longer reporting an under-temperature error condition. | An enclosure temperature sensor is no longer reporting an under-temperature error condition. | No action is required. | N | No |
2827 | Enclosure enclosure-number temperature sensor sensor-name has detected an under-temperature warning condition. | An enclosure temperature sensor is reporting an under-temperature warning condition. | Check that the enclosure power supplies are functioning properly. If a problem exists, contact your authorized service provider. | W | Yes |
2828 | Enclosure enclosure-number temperature sensor sensor-name is no longer reporting an under-temperature warning condition. | An enclosure temperature sensor is no longer reporting an under-temperature warning condition. | No action is required | N | No |
2833 | Enclosure enclosure-number voltage sensor sensor-name has detected an over-voltage failure condition. | An enclosure voltage sensor has reported an over-voltage failure condition. | Check the power and cooling modules. | E | Yes |
2834 | Enclosure enclosure-number voltage sensor sensor-name is no longer reporting an over-voltage failure condition. | An enclosure voltage sensor is no longer reporting an over-voltage failure condition. | No action is required. | N | No |
2835 | Enclosure enclosure-number voltage sensor sensor-name has detected an over-voltage warning condition. | An enclosure voltage sensor has reported an over-voltage warning condition. | Check the power and cooling modules. | W | Yes |
2836 | Enclosure enclosure-number voltage sensor sensor-name is no longer reporting an over-voltage warning condition. | An enclosure voltage sensor is no longer reporting an over-voltage warning condition. | No action is required. | N | No |
2837 | Enclosure enclosure-number voltage sensor sensor-name has detected an under-voltage failure condition. | An enclosure voltage sensor has reported an under-voltage failure condition. | Check the power and cooling modules. | E | Yes |
2838 | Enclosure enclosure-number voltage sensor sensor-name is no longer reporting an under-voltage failure condition. | An enclosure voltage sensor is no longer reporting an under-voltage failure condition. | No action is required. | N | No |
2839 | Enclosure enclosure-number voltage sensor sensor-name has detected an under-voltage warning condition. | An enclosure voltage sensor has reported an under-voltage warning condition. | Check the power and cooling modules. | W | Yes |
2840 | Enclosure enclosure-number voltage sensor sensor-name is no longer reporting an under-voltage warning condition. | An enclosure voltage sensor is no longer reporting an under-voltage warning condition. | No action is required. | N | No |
2841 | Enclosure enclosure-number current sensor sensor-name has detected an over-current failure condition. | An enclosure current sensor has reported an over-current failure condition. | Check the power and cooling modules. | E | Yes |
2842 | Enclosure enclosure-number current sensor sensor-name is no longer reporting an over-current failure condition. | An enclosure current sensor is no longer reporting an over-current failure condition. | No action is required. | N | No |
2843 | Enclosure enclosure-number current sensor sensor-name has detected an over-current warning condition. | An enclosure current sensor has reported an over-current warning condition. | Check the power and cooling modules. | W | Yes |
2844 | Enclosure enclosure-number current sensor sensor-name is no longer reporting an over-current warning condition. | An enclosure current sensor is no longer reporting an over-current warning condition. | No action is required. | N | No |
2845 | Enclosure enclosure-number (serial number serial-number) component component-name is reporting a status of component-status. | The status of an enclosure component has changed. | Check that all components are operating normally. | E | Yes |
2846 | Enclosure enclosure-number (serial number serial-number) component component-name is reporting a status of component-status. | The status of an enclosure component has changed. | Check that all components are operating normally. | W | Yes |
2847 | Enclosure enclosure-number (serial number serial-number) component component-name is reporting a status of component-status. | The status of an enclosure component has changed. | No action is required. | N | Yes |
2848 | Enclosure enclosure-number component component-name beaconing is on. | Beaconing is on for an enclosure component. | No action is required. | N | Yes |
2849 | Enclosure enclosure-number component component-name beaconing is now off. | Beaconing is now off for an enclosure component. | No action is required. | N | No |
2850 | Enclosure enclosure-number component component-name is marked failed. | An enclosure component has been marked failed. | Check that the enclosure component is operating properly. If it isn't, replace the component. | E | Yes |
2851 | Enclosure enclosure-number component component-name failure has been cleared. | An enclosure component is no longer marked failed. | No action is required. | N | No |
2852 | Enclosure enclosure-number hardware component component-name has been changed. | An enclosure hardware component changed (for example, an I/O module was removed or reinserted). | Verify that this is an expected event. | E | No |
2854 | The drive in enclosure enclosure-number slot slot-number has been powered off. | A drive was powered off. | If this is an unexpected event, check the health of the drive. | E | Yes |
2855 | The drive in enclosure enclosure-number slot slot-number has been powered on. | A drive was powered on. | No action is required. | N | No |
2856 | Enclosure enclosure-number has a warning condition. | An enclosure has a warning condition. | Check that the enclosure is operating normally. | W | Yes |
2857 | Enclosure enclosure-number warning has been cleared. | An enclosure no longer has a warning condition. | No action is required. | N | No |
2858 | Enclosure enclosure-number hardware component component-name has been changed during a maintenance procedure. | An enclosure hardware component has been changed during a maintenance procedure. | Complete the maintenance procedure. | N | No |
2859 | Enclosure enclosure-number slot slot-number has been marked failed. | An enclosure slot has been marked failed. | Replace the drive in the slot. | E | Yes |
2860 | Enclosure enclosure-number slot slot-number failure has been cleared. | An enclosure slot is no longer marked failed. | No action is required. | N | No |
2861 | Enclosure enclosure-number slot slot-number hardware has been changed outside of a maintenance procedure. | Enclosure slot hardware has been marked as changed outside of a maintenance procedure. | If the drive is unavailable, use the remove drives and add drives maintenance procedures to correct the problem. | E | No |
2863 | Enclosure enclosure-number slot slot-number hardware has been changed during a maintenance procedure. | Enclosure slot hardware has been marked as changed during a maintenance procedure. | Complete the maintenance procedure. | N | No |
2866 | Server module server-module-number has been marked failed. | A server module has been marked failed. | Check that the server module is operating normally. If it isn't, replace the server module. | E | Yes |
2867 | Server module server-module-number failure has been cleared. | A server module is no longer marked failed. | No action is required | N | No |
2868 | Enclosure enclosure-number pcm-fan-name has been marked failed. | A power and cooling module fan has been marked failed. | Check that the power and cooling module is functioning properly. If it isn't, replace the power and cooling module. | E | Yes |
2869 | Enclosure enclosure-number pcm-fan-name failure has been cleared. | A power and cooling module fan is no longer marked failed. | No action is required. | N | No |
2870 | Enclosure enclosure-number is in lockdown mode. | An enclosure is in lockdown mode. | Contact your authorized service provider. | E | Yes |
2871 | Enclosure enclosure-number is no longer in lockdown mode. | An enclosure is no longer in lockdown mode. | No action is required. | N | No |
2872 | Enclosure enclosure-number hardware is unsupported (vendor: enclosure-vendor, product: enclosure-model, rev: enclosure-firmware-revision, wwid: enclosure-wwid). | Enclosure hardware is unsupported. | Contact your authorized service provider. | E | Yes |
2873 | Enclosure enclosure-number hardware is now supported (vendor: enclosure-vendor, product: enclosure-model, rev: enclosure-firmware-revision, wwid: enclosure-wwid). | Enclosure hardware is now supported. | No action is required. | N | No |
2876 | Enclosure enclosure-number slot slot-number drive hardware is unsupported (vendor: drive-vendor, product: drive-model, rev: drive-firmware-revision, wwid: drive-wwid). | Data or database drive hardware is unsupported. | Contact your authorized service provider. | E | Yes |
2877 | Enclosure enclosure-number slot slot-number drive hardware is now supported (vendor: drive-vendor, product: drive-model, rev: drive-firmware-revision, wwid: drive-wwid). | Data or database drive hardware is now supported. | No action is required. | N | No |
2878 | Enclosure enclosure-number SAS expanders have different firmware versions. | The enclosure SAS expanders have different firmware versions. | Update the enclosure SAS expander firmware. | E | Yes |
2879 | Enclosure enclosure-number SAS expanders no longer have different firmware versions. | The enclosure SAS expanders now have matching firmware versions. | No action is required. | N | No |
2880 | Enclosure enclosure-number is not reporting status information. | An enclosure is not reporting status information. | Contact your authorized service provider. | E | Yes |
2881 | Enclosure enclosure-number is now reporting status information. | An enclosure is now reporting status information. | No action is required. | N | No |
2882 | Enclosure enclosure-number (serial number serial-number) slot slot-number is reporting a status of slot-status. | The status of an enclosure slot changed. | No action is required. | E | Yes |
2883 | Enclosure enclosure-number (serial number serial-number) slot slot-number is reporting a status of slot-status. | The status of an enclosure slot changed. | No action is required. | W | Yes |
2884 | Enclosure enclosure-number (serial number serial-number) slot slot-number is reporting a status of slot-status. | The status of an enclosure slot changed. | No action is required | N | Yes |
2885 | Enclosure enclosure-number (serial number serial-number) is reporting a status of enclosure-status. | The status of the enclosure has changed. | Check that the enclosure is operating normally. | E | Yes |
2886 | Enclosure enclosure-number (serial number serial-number) is reporting a status of enclosure-status. | The status of the enclosure has changed. | Check that the enclosure is operating normally. | W | Yes |
2887 | Enclosure enclosure-number (serial number serial-number) is reporting a status of enclosure-status. | The status of the enclosure has changed. | No action is required. | N | Yes |
2888 | A component in enclosure enclosure-number is reporting a failure. | An enclosure component reported a failure. | Check that the enclosure component is operating correctly. | E | Yes |
2889 | Enclosure enclosure-number failure has been cleared. | An enclosure component is longer reporting a failure. | No action is required. | N | No |
2890 | Enclosure enclosure-number hardware has been changed. | Enclosure hardware changed | Verify that this is an expected event. If it isn't, contact your authorized service provider. | E | No |
2891 | Enclosure enclosure-number hardware has been changed during a maintenance procedure. | Enclosure hardware changed during a maintenance procedure | Complete the maintenance procedure. | E | No |
2892 | Enclosure enclosure-number beaconing is on. | Beaconing is on for an enclosure. | No action is required. | N | Yes |
2893 | Enclosure enclosure-number beaconing is now off. | Beaconing is now off for an enclosure. | No action is required. | N | No |
2894 | Enclosure enclosure-number slot slot-number has been marked failed. | An enclosure slot has been marked failed. | Replace the drive in the slot. | N | No |
2895 | Server module server-module-number beaconing is on. | Beaconing is on for a server module. | No action is required. | N | Yes |
2896 | Server module server-module-number beaconing is now off. | Beaconing is now off for a server module. | No action is required. | N | No |
2897 | Server module server-module-number is reporting a status of server-module-status. | The status of a server module has changed. | Check that all server module components are operating normally. | E | Yes |
2898 | Server module server-module-number is reporting a status of server-module-status. | The status of a server module has changed. | Check that all server module components are operating normally. | W | Yes |
2899 | Server module server-module-number is reporting a status of server-module-status. | The status of server module has changed. | No action is required. | N | Yes |
2900 | Server module server-module-number drive initialization is complete (data: total-number-of-data-drives-processed, failed: number-of-failed-drives, unavailable: number-of-unavailable-drives, discovered: number-of-drives-discovered, database: total-number-of-database-drives-processed). | Server module drive initialization is complete. | No action is required. | N | No |
2901 | Drive is unavailable on server module server-module-number (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive either was removed outside of a maintenance procedure or has become unavailable. | Use the HCP S Series Management Console to check the health of the drive. | E | Yes |
2902 | Drive is now available on server module server-module-number (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive that was unavailable is now available. | No action is required. | N | No |
2903 | Server module server-module-number detected a new drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A new data or database drive was detected. | Complete the active maintenance procedure. | N | No |
2904 | Server module server-module-number added a data drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data drive was added. | No action is required. | N | No |
2905 | Server module server-module-number formatted a data drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data drive was formatted. | No action is required. | N | No |
2906 | Server module server-module-number removed a drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was removed. | No action is required. | N | No |
2907 | Server module server-module-number detected new drive firmware (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | New data or database drive firmware was detected. | No action is required. | N | No |
2908 | Server module server-module-number marked a drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive has been marked failed. | Remove or replace the drive. | E | No |
2909 | Server module server-module-number detected a new drive outside of a maintenance procedure and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was added outside of a maintenance procedure and has been marked failed. | Use maintenance procedures to remove and then add the drive. | E | No |
2910 | Server module server-module-number failed to add a drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed because it could not be added. | Replace the drive. | E | No |
2911 | Server module server-module-number detected a moved drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed because it was moved. | Use maintenance procedures to remove and then add the drive. | E | No |
2912 | Server module server-module-number detected an incorrect drive WWID and marked the drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed due to an incorrect WWID. | Replace the drive. | E | No |
2913 | Server module server-module-number detected an incorrect drive serial number and marked the drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed due to an incorrect serial number. | Replace the drive. | E | No |
2914 | Server module server-module-number detected an unavailable drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed because it is unavailable. | Replace the drive. | E | No |
2915 | Server module server-module-number failed to format a data drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A drive was marked failed because it could not be formatted. | Use maintenance procedures to remove and then add the drive. If that doesn't fix the problem, replace the drive. | E | No |
2916 | Server module server-module-number failed to add a data drive due to an I/O error (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data drive could not be added due to an I/O error. | Use maintenance procedures to remove and then add the drive. If that doesn't fix the problem, replace the drive. | E | No |
2917 | Server module server-module-number failed to remove a drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A drive could not be removed. | Use a maintenance procedure to remove or replace the drive. If that doesn't fix the problem, contact your authorized service provider. | E | No |
2918 | Server module server-module-number added a database drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A server module added a database drive. | No action is required. | N | No |
2919 | Drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive failed. | Remove or replace the drive. | E | Yes |
2920 | Drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive failed. | Remove or replace the drive. | N | Yes |
2921 | Drive unavailable (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive either was removed outside of a maintenance procedure or has become unavailable. | Use the HCP S Series Management Console to check the health of the drive. | E | Yes |
2922 | Drive unavailable (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive either was removed outside of a maintenance procedure or has become unavailable. | Use the HCP S Series Management Console to check the health of the drive. | N | Yes |
2923 | Server module server-module-number marked a drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive has been marked failed. | Remove or replace the drive. | N | No |
2924 | Server module server-module-number detected a new drive outside of a maintenance procedure and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was added outside of a maintenance procedure and has been marked failed. | Use maintenance procedures to remove and then add the drive. | N | No |
2925 | Server module server-module-number failed to add a drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed because it could not be added. | Replace the drive. | N | No |
2926 | Server module server-module-number detected a moved drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed because it was moved. | Use maintenance procedures to remove and then add the drive. | N | No |
2927 | Server module server-module-number detected an incorrect drive WWID and marked the drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed due to an incorrect WWID. | Replace the drive. | N | No |
2928 | Server module server-module-number detected an incorrect drive serial number and marked the drive failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed due to an incorrect serial number. | Replace the drive. | N | No |
2929 | Server module server-module-number detected an unavailable drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive was marked failed because it is unavailable. | Replace the drive. | N | No |
2930 | Server module server-module-number failed to format a data drive and marked it failed (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A drive was marked failed because it could not be formatted. | Use maintenance procedures to remove and then add the drive. If that doesn't fix the problem, replace the drive. | N | No |
2931 | Server module server-module-number failed to add a data drive due to an I/O error (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data drive could not be added due to an I/O error. | Use maintenance procedures to remove and then add the drive. If that doesn't fix the problem, replace the drive. | N | No |
2932 | Server module server-module-number failed to remove a drive (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A drive could not be removed. | Use a maintenance procedure to remove or replace the drive. If that doesn't fix the problem, contact your authorized service provider. | N | No |
2933 | Drive is unavailable on server module server-module-number (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data or database drive either was removed outside of a maintenance procedure or has become unavailable. | Use the HCP S Series Management Console to check the health of the drive. | N | Yes |
2934 | Server module server-module-number detected that the data drive in enclosure enclosure-number slot slot-number was moved to enclosure enclosure-number slot slot-number (enclosure: enclosure-number, slot: slot-number, serial number: drive-serial-number, wwid: drive-wwid). | A data drive was moved. | No action is required. | N | No |
2951 | Enclosure enclosure-number is unavailable on server module server-module-number (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure is unavailable. | Contact your authorized service provider. | E | Yes |
2952 | Enclosure enclosure-number is now available on server module server-module-number (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure that was unavailable is now available. | No action is required. | N | No |
2953 | Server module server-module-number detected a new enclosure during a maintenance procedure (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | A new enclosure was detected during a maintenance procedure. | Complete the maintenance procedure. | N | No |
2954 | Server module server-module-number added an enclosure (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was added. | No action is required. | N | No |
2955 | Server module server-module-number removed an enclosure during a maintenance procedure (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was removed. | No action is required. | N | No |
2956 | Server module server-module-number detected new enclosure firmware (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | New enclosure firmware was detected. | No action is required. | N | No |
2957 | Server module server-module-number marked an enclosure failed (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed. | Contact your authorized service provider. | E | No |
2958 | Server module server-module-number detected a new enclosure outside of a maintenance procedure and marked it as failed (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was added outside of a maintenance procedure and was marked failed. | Contact your authorized service provider. | E | No |
2959 | Server module server-module-number detected an incorrect enclosure WWID and marked the enclosure failed (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed due to an incorrect WWID. | Contact your authorized service provider. | E | No |
2960 | Server module server-module-number detected an incorrect enclosure serial number and marked the enclosure failed (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed due to an incorrect serial number. | Contact your authorized service provider. | E | No |
2961 | Server module server-module-number detected that an enclosure is unavailable and marked it failed (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed because it is unavailable. | Contact your authorized service provider. | E | No |
2962 | Enclosure enclosure-number failed (serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed. | Contact your authorized service provider. | E | Yes |
2963 | Enclosure enclosure-number is unavailable (serial number: enclosure-serial number, wwid: enclosure-wwid). | An enclosure is unavailable. | Contact your authorized service provider. | E | Yes |
2964 | Server module server-module-number enclosure initialization is complete (available: total-number-of-enclosures-processed, failed: number-of-failed-enclosures, unavailable: number-of-unavailable-enclosures, discovered: number-of-enclosures-discovered). | Server module enclosure initialization is complete. | No action is required. | N | No |
2967 | Enclosure enclosure-number is unavailable on server module server-module-number (enclosure: enclosure-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure is unavailable. | Contact your authorized service provider. | N | Yes |
2968 | Enclosure enclosure-number is unavailable (serial number: enclosure-serial number, wwid: enclosure-wwid). | An enclosure is unavailable. | Contact your authorized service provider. | N | Yes |
2969 | Enclosure enclosure-number failed (serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed. | Contact your authorized service provider. | N | Yes |
2970 | Enclosure enclosure-number failed (FRU part number: part-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed. | Contact your authorized service provider. | E | Yes |
2971 | Enclosure enclosure-number failed (FRU part number: part-number, serial number: enclosure-serial-number, wwid: enclosure-wwid). | An enclosure was marked failed. | Contact your authorized service provider. | N | Yes |
2980 | Server module server-module-number SAS port sas-port-number is connected to enclosure enclosure-number I/O module iom-number port sas-port-number but should be connected to enclosure enclosure-number I/O module iom-number port port-number. | A server module SAS port is connected to an incorrect I/O module port. | Contact your authorized service provider. | E | Yes |
2981 | Server module server-module-number SAS port sas-port-number is no longer connected to an incorrect enclosure I/O module port. | A server module SAS port is no longer connected to an incorrect enclosure I/O module port. | No action is required. | N | No |
2982 | Server module server-module-number SAS port sas-port-number should be connected to enclosure enclosure-number I/O module iom-number port sas-port-number but is not. | A server module SAS port is not connected to an enclosure I/O module port but should be. | Contact your authorized service provider. | E | Yes |
2983 | Server module server-module-number SAS port sas-port-number connection is no longer missing. | A server module SAS port connection is no longer missing. | No action is required. | N | No |
2984 | Server module server-module-number SAS port sas-port-number is connected to enclosure enclosure-number I/O module iom-number port sas-port-number but should not be. | A server module SAS port is unexpectedly connected to an I/O module port. | Contact your authorized service provider. | E | Yes |
2985 | Server module server-module-number SAS port sas-port-number no longer has an unexpected connection to an enclosure I/O module port. | A server module SAS port no longer has an unexpected connection to an enclosure I/O module port. | No action is required. | N | No |
2986 | Enclosure enclosure-numbersas-port-identification is connected to sas-port-identification but should be connected to sas-port-identification. | An enclosure I/O module port is connected to an incorrect enclosure I/O module port. | Contact your authorized service provider. | E | Yes |
2987 | Enclosure enclosure-number sas-port-identification is no longer connected to an incorrect SAS port. | An I/O module port is no longer connected to an incorrect SAS port. | No action is required. | N | No |
2988 | Enclosure enclosure-number sas-port-identification should be connected to sas-port-identification but is not. | An I/O module port is not connected to a SAS port but should be. | Contact your authorized service provider. | E | Yes |
2989 | Enclosure enclosure-number sas-port-identification connection is no longer missing. | An I/O module port connection is no longer missing. | No action is required. | N | No |
2990 | Enclosure enclosure-number sas-port-identification is connected to sas-port-identification but should not be. | An I/O module port is unexpectedly connected to a SAS port. | Contact your authorized service provider. | E | Yes |
2991 | Enclosure enclosure-number sas-port-identification is no longer connected to a SAS port. | An I/O module port is no longer connected to a SAS port. | No action is required. | N | No |
2992 | Enclosure 1 rear SAS port port-number is connected to enclosure enclosure-number I/O module iom-number port sas-port-number but should be connected to enclosure enclosure-number I/O module iom-number port sas-port-number. | A rear SAS port is connected to an incorrect I/O module port. | Contact your authorized service provider. | E | Yes |
2993 | Enclosure 1 rear SAS port sas-port-number is no longer connected to an incorrect I/O module port. | A rear SAS port is no longer connected to an incorrect I/O module port. | No action is required. | N | No |
2994 | Enclosure 1 rear SAS port sas-port-number should be connected to enclosure enclosure-number I/O module iom-number port sas-port-number but is not. | A rear SAS port is not connected to an I/O module port but should be. | Contact your authorized service provider. | E | Yes |
2995 | Enclosure 1 rear SAS port sas-port-number is now connected to an I/O module port. | A rear SAS port is now connected to an I/O module port. | No action is required. | N | No |
2996 | Enclosure 1 rear SAS port sas-port-number is connected to enclosure enclosure-number I/O module iom-number port sas-port-number but should not be. | A rear SAS port is unexpectedly connected to an I/O module port. | Contact your authorized service provider. | E | Yes |
2997 | Enclosure 1 rear SAS port sas-port-number is no longer connected to an I/O module port. | A rear SAS port is no longer connected to an I/O module port. | No action is required. | N | No |
3000 | The ''configuration-setting'' value changed from ''old-value'' to ''new-value''. | A user changed a configuration value. | No action is required. | N | No |
3001 | The ''configuration-setting'' value changed from ''old-value'' to ''new-value''. | A user changed a configuration value. | No action is required. | N | No |
3004 | A user account was created with username username, enabled true/false. | A user created a user account. | No action is required. | N | No |
3005 | The user account with username username and user ID user-account-id was deleted. | A user deleted a user account. | No action is required. | N | No |
3006 | Bucket bucket-name was created with bucket owner username. | A user created a bucket. | No action is required. | N | No |
3007 | Bucket bucket-name with bucket owner username was deleted. | A user deleted a bucket. | No action is required. | N | No |
3008 | The user account with username username was updated: configuration setting changed from ''old-value'' to ''new-value''. | A user updated a user account. | No action is required. | N | No |
3009 | New access keys were generated for the user account with username {0}. | A user generated new access keys. | No action is required. | N | No |
3010 | The minimum TLS version has been changed from 'old-tls-setting' to 'new-tls-setting'. | A user changed the minimum TLS version. | No action is required. | N | No |
3015 | The exclusive SSH keys in the SSH key package with ID key-package-id have been installed on the HCP S Series Node and are now active. | A user uploaded an SSH key package, and the SSH keys in the package were successfully installed on the HCP S Series Node. | No action is required. | N | No |
3017 | Exclusive SSH keys have been revoked. The distributor-key default SSH keys are now active. | A user revoked the exclusive SSH keys that were installed on the HCP S Series Node. | No action is required. | W | No |
3018 | An attempt to install the exclusive SSH keys in the SSH key package with ID key-package-id failed. | An attempt to install exclusive SSH keys failed. | Try uploading the SSH key package again. If the problem persists, contact your authorized service provider. | E | No |
3019 | An attempt to revoke exclusive SSH keys failed. | An attempt to revoke exclusive SSH keys failed. | Try revoking the exclusive SSH keys again. If the problem persists, contact your authorized service provider. | E | No |
3131 | The HCP S Series Node was shut down; reason: reason | A user shut down the HCP S Series Node. | No action is required. | N | No |
3132 | The HCP S Series Node was restarted; reason: reason | A user restarted the HCP S Series Node. | No action is required. | N | No |
3133 | Server module server-module-number was shut down; reason: reason | A user shut down a server module. | No action is required. | N | No |
3134 | Server module server-module-number was restarted; reason: reason | A user restarted a server module. | No action is required. | N | No |
3135 | Server module server-module-number was powered on; reason: reason | A user powered on a server module. | No action is required. | N | No |
3136 | An attempt to power on the server module server-module-number failed (originating IP ip-address). | A user request to power on a server module failed. | No action is required. | E | No |
3137 | number-of-data-drives data drives have failed or are unavailable. | The data drive failed/unavailable threshold has been exceeded. | Remove or replace the drives. | W | Yes |
3138 | One or more data drives may be failed or unavailable, but data drive replacement is not required at this time. | The data drive failed/unavailable threshold is no longer exceeded. | No action is required. | N | No |
3139 | The HCP S Series Node supports a maximum of max-number-of-enclosures enclosures. | The HCP S Series Node has more enclosures than are supported. | Check that the correct server modules are installed in the HCP S Series Node. If the problem persists, contact your HCP support center. | W | Yes |
3140 | The HCP S Series Node no longer has more enclosures than the supported maximum of max-number-of-enclosures. | The HCP S Series Node now has a supported number of enclosures. | No action is required. | N | No |
3161 | Internal logs were marked with search code search-code and message message-text. | A user inserted a message into the HCP S Series Node internal logs. | No action is required. | N | No |
3162 | A log download started. | A user has requested a download of the HCP S Series Node internal logs. | No action is required. | N | No |
3163 | A log download with search code search-code failed: failure-reason | A requested download of the HCP S Series Node internal logs failed. | Try to download the logs again. If that fails, contact your authorized service provider. | W | No |
3164 | Log download preparation with search code search-code started on server module server-module-number. | The HCP S Series Node has started preparing the internal logs for download on an individual server module. | No action is required. | N | No |
3165 | Log download preparation with search code search-code successfully finished on server module server-module-number. | The HCP S Series Node has finished preparing the internal logs for download on an individual server module. | No action is required. | N | No |
3166 | Log download preparation with search code search-code failed on server module server-module-number. Continuing with next server module. | The HCP S Series Node failed to prepare the internal logs for download on an individual server module and is continuing with the next server module. | No action is required. | W | No |
3167 | Log download final preparation has started. | The HCP S Series Node has started the final preparation of the internal logs for download. | No action is required. | N | No |
3168 | Log download final preparation is complete. | Log download final preparation is complete, and the HCP S Series Node internal logs are ready to be downloaded. | No action is required. | N | No |
3169 | Log download to client has started. | The HCP S Series Node internal logs have begun streaming to an HTTP client. | No action is required. | N | No |
3170 | Log download is complete. | The HCP S Series Node internal logs have been downloaded. | No action is required. | N | No |
4000 | The internal database is not being replicated. | The internal database on one server module cannot connect to the internal database on the other server module. | Check the S Series Node network configuration. | E | Yes |
4001 | The internal database is being replicated. | The internal database is being replicated from one server module to the other. | No action is required. | N | No |
4002 | The HCP S Series Node failed to back up the internal database. | The HCP S Series Node failed to back up the internal database. | If this happens repeatedly, contact your authorized service provider. | E | No |
5000 | Storage is percent-full% full. | Storage is almost full. | Add more capacity or free up space. | W | Yes |
5001 | Storage is percent-full% full. | Storage is full. | Add more capacity or free up space. | E | Yes |
5002 | Irreparable objects have been detected. | Too many data drives are unavailable or failed. | Contact your authorized service provider. | E | Yes |
5003 | Objects may be unavailable due to insufficient recovery sources. | Too many data drives are unavailable or failed. | Check the hardware status and correct any issues. If the problem persists, contact your authorized service provider. | E | No |
5004 | Data cannot be fully protected due to not enough drives or insufficient free space. | Not enough drives or free space is available to perform repairs. | Replace failed drives, add more capacity, or free up space. | E | No |
5005 | The internal database update is complete. | The internal database update finished. | No action is required. | N | No |
5006 | The internal database update has encountered an error. | The internal database update process encountered an error. | Contact your authorized service provider. | E | No |
5007 | Cannot perform metadata operations due to insufficient free space. Data access has been disabled. | Not enough free space is available to perform metadata operations. Data access has been disabled. | Contact your authorized service provider. | E | Yes |
5008 | Storage is percent-full% full. | Storage is almost full. | Add more capacity or free up space. | W | Yes |
5211 | The SSL server certificate has been replaced. | A user generated a new SSL server certificate for the HCP S Series Node. | No action is required. | N | No |
5212 | An attempt to replace the SSL server certificate failed. | A failure occurred during an attempt to replace the SSL server certificate on the HCP S Series Node. | Contact your authorized service provider. | E | No |
5213 | SSL server certificate distinguished-name expires on expiration-date. | The SSL server certificate for this HCP S Series Node expires soon. If the certificate expires, clients will need to accept the expired certificate in order to use HTTPS for access to the HCP S Series Node. | Install a new SSL server certificate with a later expiration date. | W | Yes |
5214 | SSL server certificate distinguished-name expired on expiration-date. | The SSL server certificate for this HCP S Series Node has expired. Clients must accept the expired certificate in order to use HTTPS for access to the HCP S Series Node. | Install a new SSL server certificate with a later expiration date. | E | Yes |
5215 | A new CSR has been generated. | A user generated a new CSR for the HCP S Series Node. | No action is required. | N | No |
5300 | The HCP S Series Node is being updated to software-release-number. | A user has started an HCP S Series Node update. | No action is required. | N | No |
5301 | The HCP S Series Node has been updated to software-release-number. | The HCP S Series Node has been successfully updated. | No action is required. | N | No |
5302 | An unexpected error occurred during an update of the HCP S Series Node. | An unexpected error occurred during an update of the HCP S Series Node. | Contact your authorized service provider. | E | No |
5350 | A new license has been applied to the HCP S Series Node. | A user applied a new license to the HCP S Series Node. | No action is required. | N | No |
5500 | Server module server-module-number has been changed. | A user removed, reinserted, or replaced a server module. | Verify that this is an expected event. | E | No |
5501 | Enclosure enclosure-number iom-number hardware is unsupported (vendor: iom-vendor, product: iom-model, rev: iom-firmware-revision, wwid: iom-wwid). | I/O module hardware is unsupported. | Contact your authorized service provider. | E | Yes |
5502 | Enclosure enclosure-number iom-number hardware is now supported (vendor: iom-vendor, product: iom-model, rev: iom-firmware-revision, wwid: iom-wwid). | I/O module hardware is now supported. | No action is required. | N | No |
5503 | Enclosure enclosure-number is marked failed. | An enclosure has been marked failed. | Check that the enclosure is operating properly. If it isn't, replace the enclosure. | N | No |
5504 | Enclosure enclosure-number SAS expanders have different firmware versions. | The SAS expander firmware is in the process of being upgraded. | No action is required. | N | Yes |
5505 | Enclosure enclosure-number expander sas-expander-number hardware is unsupported (vendor: vendor-name, FRU part number: part-number, product: product-name, rev: firmware-revision, SAS address: sas-address). | An enclosure contains unsupported SAS expander hardware. | Contact your authorized service provider. | E | Yes |
5506 | Enclosure enclosure-number expander sas-expander-number hardware is now supported (vendor: vendor-name, FRU part number: part-number, product: product-name, rev: firmware-revision, SAS address: sas-address). | An enclosure now contains supported SAS expander hardware. | No action is required. | N | No |
5507 | The bay-type cover for enclosure enclosure-number has been opened outside of a maintenance procedure. | An enclosure cover is open outside of a maintenance procedure. | Close the enclosure cover. | E | Yes |
5508 | The bay-type cover for enclosure enclosure-number has been opened during a maintenance procedure. | An enclosure cover is open during a maintenance procedure. | No action is required. | N | No |
5509 | The bay-type cover for enclosure enclosure-number has been closed. | An enclosure cover was closed. | No action is required. | N | No |
5510 | Enclosure enclosure-number power supply power-supply-number hardware is unsupported (vendor: vendor-name, product: product-name, fwRev: firmware-revision, wwid: power-supply-wwid). | An enclosure contains an unsupported power supply. | Contact your authorized service provider. | E | Yes |
5511 | Enclosure enclosure-number power supply power-supply-number hardware is now supported (vendor: vendor-name, product: product-name, fwRev: firmware-revision, wwid: power-supply-wwid). | An enclosure now contains a supported power supply. | No action is required. | N | No |
5512 | Enclosure enclosure-number fan fan-number hardware is unsupported (vendor: vendor-name, part number : part-number, wwid: fan-wwid). | An enclosure contains an unsupported fan. | Contact your authorized service provider. | E | Yes |
5513 | Enclosure enclosure-number fan fan-number hardware is now supported (vendor: vendor-name, part number : part-number, wwid: fan-wwid). | An enclosure now contains a supported fan. | No action is required. | N | No |
5514 | Enclosure enclosure-number power-supply-number has been marked failed. | A power supply has been marked failed. | Check that the power supply is operating normally. If it isn't, replace the power supply. | E | Yes |
5515 | Enclosure enclosure-number power-supply-number failure has been cleared. | A power supply is no longer marked failed. | No action is required. | N | No |
5516 | Enclosure enclosure-number fan-number has been marked failed. | A fan has been marked failed. | Check that the fan is operating normally. If it isn't, replace the fan. | E | Yes |
5517 | Enclosure enclosure-number fan-number has been cleared. | A fan is no longer marked failed. | No action is required. | N | No |
5518 | Enclosure enclosure-number power supply power-supply-number has detected a DC over-voltage condition. | A power supply has reported a DC over-voltage condition. | Check the power supply. | E | Yes |
5519 | Enclosure enclosure-number power supply power-supply-number is no longer reporting a DC over-voltage condition. | A power supply is no longer reporting a DC over-voltage condition. | No action is required. | N | No |
5520 | Enclosure enclosure-number power supply power-supply-number has detected a DC under-voltage condition. | A power supply has reported a DC under-voltage condition. | Check the power supply. | E | Yes |
5521 | Enclosure enclosure-number power supply power-supply-number is no longer reporting a DC under-voltage condition. | A power supply is no longer reporting a DC under-voltage condition. | No action is required. | N | No |
5522 | Enclosure enclosure-number power supply power-supply-number has detected a DC over-current condition. | A power supply has reported a DC over-current condition. | Check the power supply. | E | Yes |
5523 | Enclosure enclosure-number power supply power-supply-number is no longer reporting a DC over-current condition. | A power supply is no longer reporting a DC over-current condition. | No action is required. | N | No |
5524 | Enclosure enclosure-number power supply power-supply-number has detected an over-temperature failure condition. | A power supply has reported an over-temperature failure condition. | Check the power supply. | E | Yes |
5525 | Enclosure enclosure-number power supply power-supply-number is no longer reporting an over-temperature failure condition. | A power supply is no longer reporting an over-temperature failure condition. | No action is required. | N | No |
5526 | Enclosure enclosure-number power supply power-supply-number has detected an over-temperature warning condition. | A power supply has reported an over-temperature warning condition. | Check the power supply. | W | Yes |
5527 | Enclosure enclosure-number power supply power-supply-number is no longer reporting an over-temperature warning condition. | A power supply is no longer reporting an over-temperature warning condition. | No action is required. | N | No |
5528 | Enclosure enclosure-number power supply power-supply-number has detected an AC power failure. | A power supply has reported an AC power failure. | Check the power supply. | E | Yes |
5529 | Enclosure enclosure-number power supply power-supply-number is no longer reporting an AC power failure. | A power supply is no longer reporting an AC power failure. | No action is required. | N | No |
5530 | Enclosure enclosure-number power supply power-supply-number has detected a DC power failure. | A power supply has reported a DC power failure. | Check the power supply. | E | Yes |
5531 | Enclosure enclosure-number power supply power-supply-number is no longer reporting a DC power failure. | A power supply is no longer reporting a DC power failure. | No action is required. | N | No |
5532 | Enclosure enclosure-number power supply power-supply-number is powered off. | A power supply is powered off. | Check the power supply. | E | Yes |
5533 | Enclosure enclosure-number power supply power-supply-number was powered on. | A power supply was powered on. | No action is required. | N | No |
5534 | Enclosure enclosure-number fan-number is off. | A fan is off. | Check the fan. | E | Yes |
5535 | Enclosure enclosure-number fan-number is on. | A fan that was off is now on. | No action is required. | N | No |
5536 | Enclosure enclosure-number power supply power-supply-number is not compatible with the other power supply in the enclosure and needs to be replaced. | The power supplies in an enclosure are not compatible with each other. | Contact your authorized server provider. | E | Yes |
5537 | Enclosure enclosure-number power supply power-supply-number has been replaced. | The power supplies in an enclosure are now compatible with each other. | No action is required. | N | No |
5550 | Enclosure 1 VPD firmware backup has been created on server module server-module-number. | VPD firmware for enclosure 1 was successfully backed up on a server module. | No action is required. | N | No |
5551 | Failed to create VPD firmware backup for enclosure 1 on server module server-module-number. | VPD firmware for enclosure 1 could not be backed up on a server module. | No action is required. | N | No |
5552 | Enclosure 1 VPD firmware has been restored on server module server-module-number. | VPD firmware for enclosure 1 was successfully restored on a server module. | No action is required. | N | No |
5553 | Failed to restore VPD firmware for enclosure 1 on server module server-module-number. | VPD firmware for enclosure 1 could not be restored on a server module. | No action is required. | E | No |
5600 | An OS SSD in server module server-module-number is percent-worn% worn (serial number: ssd-serial-number, wwid: ssd-wwid). | An OS SSD is close to the end of its expected life span. | Contact your authorized service provider. | W | Yes |
5700 | maintenance-procedure-type maintenance procedure is still active and will time out in number-of-minutes minute(s). | A maintenance procedure is still active. | Complete or cancel the active maintenance procedure. | N | No |
5800 | Internal status files (file-list) on server module server-module-number are not up to date. The oldest update time is date-time. | One or more internal status files are out of date. | Contact your authorized service provider. | E | Yes |
5801 | Internal status files (file-list) on server module server-module-number are not up to date. The oldest update time is date-time. | One or more internal status files are out of date. | No action is required. | W | No |
5900 | Server module server-module-number network interface device-name card is unsupported (vendor: vendor-name, product: product-name). | A server module network interface card is unsupported. | Contact your authorized service provider. | E | Yes |
5901 | Server module server-module-number network interface device-name card is now supported (vendor: vendor-name, product: product-name). | A server module network interface card is now supported. | No action is required. | N | No |
5902 | Server module server-module-number SAS card sas-card-number is unsupported (vendor: vendor-name, product: product-name, rev: revision). | A server module SAS card is unsupported. | Contact your authorized service provider. | E | Yes |
5903 | Server module server-module-number SAS card sas-card-number is now supported (vendor: vendor-name, product: product-name, rev: revision). | A server module SAS card is now supported. | No action is required. | N | No |
5904 | Server module server-module-number is missing a virtual IP address. | A server module is missing a virtual IP address. A virtual IP address must be specified for each physical IP address for a server module. | Specify the missing virtual IP address for the server module. | W | Yes |
5905 | Server module server-module-number is no longer missing a virtual IP address. | A server module is no longer missing a virtual IP address. | No action is required | N | No |
5906 | Server module server-module-number memory card memory-card-id has detected an error condition. | A server-module memory card is reporting an error. | Contact your authorized service provider. | E | Yes |
5907 | Server module server-module-number memory card memory-card-id is no longer reporting an error condition. | A server-module memory card is no longer reporting an error condition. | No action is required. | N | No |
5908 | Server module {0} access network interface card (vendor: network-interface-card-vendor, product: network-interface-card-model) does not match the corresponding card on server module server-module-number (vendor: server-module-vendor, product: server-module-model). | The server module access network interface cards do not match. | Replace the access network interface card in one of the server modules. | W | Yes |
5909 | Server module {0} access network interface card (vendor: network-interface-card-vendor, product: network-interface-card-model) matches the corrsponding card on server module server-module-number. | The server module access network interface cards match. | No action is required. | N | No |
10043 | The HCP S Series Node update to software-release-number has been restarted. | A user restarted an update of the HCP S Series Node. | No action is required. | N | No |
10044 | precheck-failure | The HCP S Series Node could not be updated due to a precheck failure. | Contact your authorized service provider. | E | No |
99999 | An unknown event occurred: event-id | The HCP S Series Node could not find an event message. | Wait for the update to finish. Then check the event log for the specified message ID. If the event message indicates a persistent error condition, contact your HCP support center. | W | No |