Specifying whether to output the CLI command-execution logs (SYSLOG)

Business Continuity Manager Installation Guide

Version
9.8.7
File Size
1.1 MB
Audience
anonymous
Part Number
MK-95HC104-41
The output method of the CLI command-execution logs is determined by the combination of the value set by the YKSETENV command, the value set by the &YKSYSLG system symbol, and the version of Business Continuity Manager to be used.

The following table lists whether to output the CLI command-execution logs and the output destination determined by the combination of the value set by the YKSETENV command, the value set by &YKSYSLG, and the version of Business Continuity Manager.

Important: The SYSLOG=CONSOLE setting of the YKSETENV command and the CONSOLE setting specified by &YKSYSLG are enabled in Business Continuity Manager 7.6 or later versions.
Table. If the settings are made by using the YKSETENV command of a version of Business Continuity Manager 7.6 or later

Value set by using the YKSETENV command

Value set by using &YKSYSLG

Version of Business Continuity Manager being run

From 6.5 to 7.5

7.6 or later

SYSLOG=YES

YES

Output to SYSLOG

Output to SYSLOG

CONSOLE

NO

No specification or specification error

SYSLOG=CONSOLE

YES

Output to SYSLOG

Output to the console

CONSOLE

NO

No specification or specification error

SYSLOG=NO

YES

Not output

CONSOLE

NO

No specification or specification error

'SYSLOG='

No specification

YES

Output to SYSLOG

Output to SYSLOG

CONSOLE

Output to the console

NO

Not output

Not output

No specification or specification error

Output to SYSLOG

Output to SYSLOG

Table. If the settings are made by using the YKSETENV command of a version of Business Continuity Manager from 6.5 to 7.5

Value set by using the YKSETENV command

Value set by using &YKSYSLG

Version of Business Continuity Manager being run

From 6.5 to 7.5

7.6 or later

SYSLOG=YES

YES

Output to SYSLOG

Output to SYSLOG#

CONSOLE

NO

No specification or specification error

SYSLOG=NO

YES

Not output

CONSOLE

NO

No specification or specification error

'SYSLOG='

No specification

YES

Output to SYSLOG

Output to SYSLOG

CONSOLE

Output to the console

NO

Not output

Not output

No specification or specification error

Output to SYSLOG

Output to SYSLOG

#
This is output to the console if the following condition is met: SYSLOG=CONSOLE was first set by using the YKSETENV command of version 7.6 or later of Business Continuity Manager, and SYSLOG=YES was then set by using the YKSETENV command of version 6.5 to 7.5 of Business Continuity Manager.