Template for setting up an environment

Business Continuity Manager Installation Guide

Version
9.8.7
File Size
1.1 MB
Audience
anonymous
Part Number
MK-95HC104-41
To set up an environment for Business Continuity Manager, run a workflow for either of the following templates.
  • YKWFSUPD

    Sets up an environment by using a dynamic procedure.

  • YKWFSUPS

    Sets up an environment by using a static procedure.

For details about environment settings, see Setting up the environment.

The following table provides a processing overview of the YKWFSUPD template.

Table. Processing overview of the YKWFSUPD template

Step

Processing overview

Automatic/ manual

1

Dynamically concatenates the LINKLIB load library#1 to LNKLST by using the SETPROG LNKLST command.

Automatic

2

Dynamically registers the LINKLIB load library#1 for APF authorization by using the SETPROG APF,ADD command.

Automatic

3

Registers the YKCONMSG command into the AUTHCMD section of the IKJTSOxx parmlib member.

Automatic

4

Copies the YKWPROC, YKALCSVC, YKSETENV, and YKDSPENV members from the cataloged procedure library#1 to the user's PROCLIB.

Automatic

5

Defines the following profiles for the RACF FACILITY class, and grants the user performing the step permission to read the profiles.

  • STGADMIN.YKA.BCM.COMMANDS

  • STGADMIN.YKA.BCM.YKQUERY

Automatic

6

Dynamically registers a user SVC by using the YKALCSVC command.

Automatic

7

Dynamically configures the Business Continuity Manager environment variable by using the YKSETENV command.

Automatic

8

Registers a license by using a license key file#2 or a license key code.

Automatic

9

  • Displays information about the installed license.

  • Displays the value specified for the Business Continuity Manager environment variable by using the YKENV command.

  • Performs verification processing for the installation and the environment settings by using the YKINSCHK command.

Automatic

10

Configure the settings required to use the ISPF panel in Business Continuity Manager in accordance with the messages displayed in the panel.

Manual

11

Configure the settings required to use the access protection function for copy groups in accordance with the messages displayed in the panel.

Manual

12

Configure the settings of the access control function for the YKFENCE command in accordance with the messages displayed in the panel.

Manual

#1 By default, the DD name of the target library is set as the suffix of the library name. (See Table 1.)

#2 If you want to register a license by using a license key file, before running this workflow, create a license key dataset by performing step 2 in Using the license key file.

The following table provides a processing overview of the YKWFSUPS template.

Table. Processing overview of the YKWFSUPS template

Step

Processing overview

Automatic/ manual

1

Statically concatenates the LINKLIB load library#1 to LNKLST by using the PROGxx parmlib member.

Automatic

2

Statically registers the LINKLIB load library#1 for APF authorization by using the PROGxx parmlib member.

Automatic

3

Registers the YKCONMSG command into the AUTHCMD section of the IKJTSOxx parmlib member.

Automatic

4

Copies the YKWPROC, YKALCSVC, YKSETENV, and YKDSPENV members from the cataloged procedure library#1 to the user's PROCLIB.

Automatic

5

Defines the following profiles for the RACF FACILITY class, and grants the user performing the step permission to read the profiles.

  • STGADMIN.YKA.BCM.COMMANDS

  • STGADMIN.YKA.BCM.YKQUERY

Automatic

6

Statically concatenates the LPALIB load library#1 to LPALST by using the LPALSTxx parmlib member.

Automatic

7

Statically registers a user SVC by using the IEASVCxx parmlib member.

Automatic

8

Statically configures the environment variable by using the IEASYMxx parmlib member.

Automatic

9

Perform re-IPL to apply the settings.

Manual

10

Registers a license by using a license key file#2 or a license key code.

Automatic

11

  • Displays information about the installed license.

  • Displays the value specified for the Business Continuity Manager environment variable by using the YKENV command.

  • Performs verification processing for the installation and the environment settings by using the YKINSCHK command.

Automatic

12

Configure the settings required to use the ISPF panel in Business Continuity Manager in accordance with the messages displayed in the panel.

Manual

13

Configure the settings required to use the access protection function for copy groups in accordance with the messages displayed in the panel.

Manual

14

Configure the settings of the access control function for the YKFENCE command in accordance with the messages displayed in the panel.

Manual

#1 By default, the DD name of the target library is set as the suffix of the library name. (See Table 1.)

#2 If you want to register a license by using a license key file, before running this workflow, create a license key dataset by performing step 2 of Using the license key file.